LATVERA
RO108 in LATVERA Golden Dusk lighting; AI concept visualization based on supplier product references.

Architectural Solutions / Complementary systems

RO108

Double Glazing Office Partition System

Discover the system

Double Glazing Office Partition System

A double-glazed office-partition family with decorative frame options and several angular junction arrangements.

Partition

A deeper double-glazed assembly

RO108 uses a double-glazed partition arrangement with a listed frame depth of 108.6 mm. The separated glazing layers and perimeter profiles should remain clear in the technical detail. The depth is a component dimension, not a claim of a particular acoustic result for every installed partition.

Junctions

Turn and branch the partition layout

The supplier describes T- and Y-junctions along with several angled connections. These allow the partition layout to respond to more than a simple rectangular room plan. Each junction should follow its selected component detail, with the glazing and decorative frame treatment carried consistently through the change of direction.

Integration

Coordinate blinds, services and openings

Internal-blind and cable provisions form part of the described options. The selected doors, hardware and service routes should be specified with the partition rather than added by visual convention. Project requirements for privacy or acoustic performance need evidence for the actual glass, frame, doors and installed connections.

A place for RO108

Considered for your space.

  • Double-glazed office partitions

A closer look

Form & detail.

The finer details

Precisely considered.

Dimensions, finishes and configuration are coordinated around your project.

System Width
108,6 mm
System Height
32,4 mm
Glass Thickness
6 / 8 / 8,76 mm

Keep the details

Your project, in detail.

Explore the system drawings and available configurations in the product documentation.

Project & technical notes

Specification requirements

Sizes, spans, loads, thermal values and applicable glazing, motors or fabrics require current supplier data and approved project documents.

Project conditions

Final appearance and performance depend on selections, site conditions, engineering, codes, permits, substrates, installation, supplier data, maintenance and the signed agreement.

Warranty and service

Coverage follows the selected system, components, approved scope, installation conditions and signed agreement. Separate components may have different coverage; the final project warranty governs.

Included scope

Permits, engineering, stamped calculations, surveys, concrete, electrical work, additional waterproofing, drainage connections, cranes, lifts and work by others are included only when expressly listed in the written proposal.

Complete technical, warranty, scope and image terms · LATVERA Catalog page 55 (opens in a new tab)