LATVERA
RWT55 in LATVERA Golden Dusk lighting; AI concept visualization based on supplier product references.

Architectural Solutions / Doors & windows

RWT55

Insulated Window and Door System

Discover the system

Insulated Window and Door System

Thermally separated aluminum joinery with a 55 mm frame family and several door and window opening options.

Construction

A thermal break within the frame

RWT55 combines a 55 mm frame depth with a 65 mm sash depth and a 14.8 mm thermal barrier. The barrier is an internal part of the profile assembly. It distinguishes this family from non-insulated RW joinery even when an installed elevation has a similar outline.

Movement

Coordinate the chosen opening

The system supports multiple door and window opening arrangements. The selected movement determines the relevant sash, fittings and clearances, so the elevation should be developed with its opening schedule. A fixed glazed panel and an operable window should retain their actual differences in frame and meeting lines.

Specification

Complete the window as an assembly

Glazing, seals, hardware and the installation detail work with the thermally separated profiles to form the finished opening. The nominal frame depth does not provide a whole-window thermal value. Project selection should use the documented configuration and the requirements of the wall or facade receiving it.

A place for RWT55

Considered for your space.

  • Door
  • Window
  • Inward Opening
  • Outward Opening
  • Bottom Hung
  • Tilt & Turn Opening
  • Vent for PVC Accessories
  • Pivot
  • Tilt & Slide
  • Folding

A closer look

Form & detail.

The finer details

Precisely considered.

Dimensions, finishes and configuration are coordinated around your project.

Frame Depth
55 mm
Vent Depth
65 mm
Wall Thickness
1,6 / 1,8 / 2 mm
Max. Glass Thickness
36 mm
Thermal Insulation Bar
14,8 mm

Keep the details

Your project, in detail.

Explore the system drawings and available configurations in the product documentation.

Project & technical notes

Specification requirements

Sizes, spans, loads, thermal values and applicable glazing, motors or fabrics require current supplier data and approved project documents.

Project conditions

Final appearance and performance depend on selections, site conditions, engineering, codes, permits, substrates, installation, supplier data, maintenance and the signed agreement.

Warranty and service

Coverage follows the selected system, components, approved scope, installation conditions and signed agreement. Separate components may have different coverage; the final project warranty governs.

Included scope

Permits, engineering, stamped calculations, surveys, concrete, electrical work, additional waterproofing, drainage connections, cranes, lifts and work by others are included only when expressly listed in the written proposal.

Complete technical, warranty, scope and image terms · LATVERA Catalog page 55 (opens in a new tab)