LATVERA
REJB50 single laminated glass Juliette guard mounted outside a window frame in LATVERA Golden Dusk lighting; AI concept visualization based on supplier product references.

Architectural Solutions / Complementary systems

REJB50

Juliette Balcony Railing System

Discover the system

Juliette Balcony Railing System

A Juliette balcony guard that places a separate laminated safety-glass barrier in front of a window or door opening.

Function

Protection at an opening, without a deck

REJB50 is a Juliette balcony system: the glass guard sits in front of a window or door opening rather than forming a projecting balcony floor. Its position and height must be coordinated with the opening behind it, keeping the guard distinct from the host window or door.

Glass

A separate safety-glass guard

The documented REJB50 assembly uses one laminated, tempered safety-glass guard panel in front of the opening. Any insulated glazing behind it belongs to the separate host window or door. The supplier lists guard-glass thicknesses of 10.76, 12.76, 16.76 and 20.76 mm; the selected build-up must follow the project requirements.

Connections

Select the fixing with the host construction

The illustrated 2026 configuration uses two slender side channels connected to the fixed outer frame, with a slim B120T02 cap along the top of the guard. The host sash and its glazing remain separate from the guard and its supports. Fixings and glass dimensions must follow the selected assembly and project requirements.

A place for REJB50

Considered for your space.

  • Juliette balcony guards
  • Window and door opening protection

A closer look

Form & detail.

The finer details

Precisely considered.

Dimensions, finishes and configuration are coordinated around your project.

Frame Depth
30,5 - 38,5 mm
Profile Width
50 mm
Glass Thickness
10,76 / 12,76 / 16,76 / 20,76 mm
Glass Width
min. 500 mm - max. 1400 mm
Glass Height
min. 800 mm - max. 1200 mm

Keep the details

Your project, in detail.

Explore the system drawings and available configurations in the product documentation.

Project & technical notes

Specification requirements

Sizes, spans, loads, thermal values and applicable glazing, motors or fabrics require current supplier data and approved project documents.

Project conditions

Final appearance and performance depend on selections, site conditions, engineering, codes, permits, substrates, installation, supplier data, maintenance and the signed agreement.

Warranty and service

Coverage follows the selected system, components, approved scope, installation conditions and signed agreement. Separate components may have different coverage; the final project warranty governs.

Included scope

Permits, engineering, stamped calculations, surveys, concrete, electrical work, additional waterproofing, drainage connections, cranes, lifts and work by others are included only when expressly listed in the written proposal.